NSN 4140-01-500-0618
Part Details | TUBEAXIAL FAN
4140-01-500-0618 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: B4033699001, B4033699-001, 7034365, 4140-01-500-0618, 01-500-0618, 4140015000618, 015000618
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | AUG 13, 2002 | 01-500-0618 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED

Cross Reference | NSN 4140-01-500-0618
Part Number | Cage Code | Manufacturer |
---|---|---|
B4033699-001 | 56996 | DEPARTMENT OF THE ARMY HQUNITED STATES ARMY COMMUNICATIONS |
7034365 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-500-0618
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 1.620 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 7.044 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
INCLOSURE TYPE | GUARDED |
AMBIENT TEMP AT FULL RATED POWER | -40.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
PRIME MOVER POWER RATING | 27.0 WATTS AND 42.1 WATTS |
OPERATING SPEED AT RATED CAPACITY IN RPM | B2850.0$$B3100.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | C220.0$C230.0 |
PHASE | THREE |
FREQUENCY IN HERTZ | B50.0$$B60.0 |
AIR FLOW RATE | 223.0 CUBIC FEET PER MINUTE MINIMUM AND 253.0 CUBIC FEET PER MINUTE MAXIMUM |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
FLOW DIRECTION | OUTWARD |
PART NAME ASSIGNED BY CONTROLLING AGENCY | SAUCER FAN 544JH, WITH L.S.W.D. |