NSN 4140-01-475-1272

Part Details | TUBEAXIAL FAN

4140-01-475-1272 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.

Alternate Parts: L12A1W65007067264, L1/2A1W6/500706-7264, FF16085, 5007067264, 500706-7264, 4140-01-475-1272, 01-475-1272, 4140014751272, 014751272

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41MAY 23, 200001-475-127204244 ( FAN, TUBEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED

Cross Reference | NSN 4140-01-475-1272
Part Number Cage Code Manufacturer
L1/2A1W6/500706-726475477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
FF1608575477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
500706-7264D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
Technical Data | NSN 4140-01-475-1272
Characteristic Specifications
STYLE DESIGNATOR FIXED
LENGTH13.000 INCHES NOMINAL
HOUSING INSIDE DIAMETER13.000 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER65.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING0.066 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM3450.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZ60.0
AIR FLOW RATE380.000 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.7 INCHES OF WATER
ENVIRONMENTAL PROTECTION SPRAY TIGHT
FLOW DIRECTION OUTWARD
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE
SPECIAL FEATURESTYPE/MODEL DESIGNATION: L1/2 A1W6,AS MODIFIED BY PUSH BUTTON OR ROTARY SWITCH
SPECIFICATION/STANDARD DATA81349-MIL-F-18953 GOVERNMENT SPECIFICATION
END ITEM IDENTIFICATIONARLEIGH BURKE CLASS DDG