NSN 4140-00-289-8862
Part Details | VANEAXIAL FAN
4140-00-289-8862 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: A3A4X5, A3A4X5, FF7778A3A4X5, A3A4X6, A3A4X5, MILF18953, D157150, D15-715-0, D157150, D15-715-0, 4140-00-289-8862, 00-289-8862, 4140002898862, 002898862
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JAN 01, 1963 | 00-289-8862 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-289-8862
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| A3A4X5 | 95402 | ELECTRIC BOAT CORPDBA ELECTRO DYNAMIC |
| A3A4X5 | 96169 | ELECTRIC BOAT CORPORATION |
| FF7778A3A4X5 | 75477 | HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA |
| A3A4X6 | 75477 | HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA |
| A3A4X5 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MILF18953 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| D15-715-0 | 90099 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDBA NORTHROP GRUMMAN MARINE SYSTEMS |
| D15-715-0 | 80231 | WESTINGHOUSE ELECTRIC CORPSTURTEVANT DIV |
Technical Data | NSN 4140-00-289-8862
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 29.625 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 21.125 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | 50.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| PRIME MOVER POWER RATING | 3.000 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 1750.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 440.0 AC |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 60.0 |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| STAGE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE |
| FEATURES PROVIDED | SAFETY IMPELLER GUARD |
| TEST DATA DOCUMENT | 81349-MILF18953 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |