NSN 4140-00-027-5150
Part Details | CENTRIFUGAL FAN
4140-00-027-5150 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.
Alternate Parts: 1NB300, 4140-00-027-5150, 00-027-5150, 4140000275150, 000275150
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 01, 1963 | 00-027-5150 | 04254 ( FAN, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED, RECTANGULAR OUTLETS
Cross Reference | NSN 4140-00-027-5150
Part Number | Cage Code | Manufacturer |
---|---|---|
1NB300 | 03522 | ZERO CORPMCLEAN ENGINEERING DIV |
Technical Data | NSN 4140-00-027-5150
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED, RECTANGULAR OUTLETS |
WIDTH | 5.812 INCHES NOMINAL |
LENGTH | 5.250 INCHES NOMINAL |
OUTLET INSIDE WIDTH | 2.188 INCHES NOMINAL |
OUTLET INSIDE HEIGHT | 2.188 INCHES NOMINAL |
HEIGHT | 5.188 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
ELECTRICAL CONNECTION TYPE | WIRE LEAD |
OPERATING SPEED AT RATED CAPACITY IN RPM | 2900.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | 60.0 |
AIR FLOW RATE | 75.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND MOISTURE RESISTANT AND VIBRATION PROOF |
MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE AND 4 UNTHREADED HOLE |
OUTLET LOCATION | M$DTPE |
DISCHARGE DIRECTION | ANGULAR DOWN AND ANGULAR UP AND HORIZONTAL AND VERTICAL DOWN AND VERTICAL UP |
SPECIAL FEATURES | POSITIONING WHEN @MTG BY OUTLET FLANGE DETERMINES DISCHARGE BLAST DIRECTION |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY THE IMPELLER ROTATION DIRECTION REQUIREMENT |