NSN 4140-00-012-3506
Part Details | CENTRIFUGAL FAN
4140-00-012-3506 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.
Alternate Parts: 810002722, 810002-722, DCFSQS201175DS, DCFS-QS201-175DS, A071856, A0-71856, DCFS1S201175DSCW6OCLOCKBLAST, DCFS1S201-175DSCW6OCLOCKBLAST, DCFSQS201CW175DF, DCFS-QS201CW-175DF, 4140-00-012-3506, 00-012-3506, 4140000123506, 000123506
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | MAY 10, 1968 | 00-012-3506 | 04254 ( FAN, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED, RECTANGULAR OUTLETS
Cross Reference | NSN 4140-00-012-3506
Part Number | Cage Code | Manufacturer |
---|---|---|
810002-722 | 12436 | BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC. |
DCFS-QS201-175DS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
A0-71856 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DCFS1S201-175DSCW6OCLOCKBLAST | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
DCFS-QS201CW-175DF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-00-012-3506
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | A FIXED, RECTANGULAR OUTLETS |
WIDTH | 3.250 INCHES NOMINAL |
LENGTH | 3.820 INCHES NOMINAL |
OUTLET INSIDE DIAMETER | 1.250 INCHES NOMINAL |
HEIGHT | 3.940 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | 0.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
PRIME MOVER POWER RATING | 21.5 WATTS |
OPERATING SPEED AT RATED CAPACITY IN RPM | 5500.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
PHASE | SINGLE |
FREQUENCY IN HERTZ | 400.0 |
AIR FLOW RATE | 27.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF AND SALT SPRAY RESISTANT |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
OUTLET LOCATION | TOP |
DISCHARGE DIRECTION | VERTICAL UP |
FEATURES PROVIDED | SAFETY IMPELLER GUARD |
SPECIAL FEATURES | POSITIONING WHEN MTG DETERMINES DISCHARGE BLAST @DIRECTION,CLASS A INSULATION MOTOR WINDINGS |