NSN 3655-01-545-4410

Part Details | TRAILER MOUNTED OXYGEN-NITROGEN GENERATING AND CHARGING PLANT

3655-01-545-4410 A mobile unit designed to produce a continuous supply of nitrogen and/or oxygen, and charge it into container(s). Excludes GENERATING AND CHARGING PLANT, OXYGEN-NITROGEN, SEMITRAILER MOUNTED.

Alternate Parts: PD11WRGRVEA06 TYPE II, PD05WRGBZOENF28 TYPE II, 3655-01-545-4410, 01-545-4410, 3655015454410, 015454410

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
36NOV 13, 200601-545-441033077 ( GENERATING AND CHARGING PLANT, OXYGEN-NITROGEN, TRAILER MOUNTED )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3655-01-545-4410
Part Number Cage Code Manufacturer
PD11WRGRVEA06 TYPE II98752WARNER ROBINS AIR LOGISTICS CENTER
PD05WRGBZOENF28 TYPE II98752WARNER ROBINS AIR LOGISTICS CENTER
Technical Data | NSN 3655-01-545-4410
Characteristic Specifications
COMPRESSOR PRIME MOVER TYPE ELECTRIC MOTOR
VOLTAGE RATING220.0 VOLTS MINIMUM AND 460.0 VOLTS MAXIMUM
FREQUENCY RATING50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE THREE
ELECTRIC GENERATOR NOT INCLUDED
DOCUMENT SOURCE98752
FURNISHED ITEMS AND QUANTITY50 FOOT (MINIMUM) LONG ELECTRICAL POWER CORD
SPECIAL FEATURESPROVIDES GASEOUS NITROGEN AT A PURITY OF 99.5% AND A PRESSURE OF 5000 PSI; PRODUCES A MINIMUM FLOWRATE OF 20 STANDARD CUBIC FEET PER MINUTE (SCFM); SHALL NOT EXCEED 90" IN LENGTH (TOW BAR UP/STOWED), 72" IN WIDTH & 62" IN HEIGHT (TOW BAR DOWN/EXTENDED); MAXIMUM WEIGHT IS 4000 LBS; TIEDOWN DEVICES THATSHALL SERVE FOR BOTH TIEDOWN & HOISTING PURPOSES SHALL BE PROVIDED; MUST HAVE THE CAPABILITY OF BEING LIFTED BY STANDARD FORKLIFT EQUIPMENT