NSN 3424-01-196-9066
Part Details | ELECTRIC HEAT TREATING FURNACE
3424-01-196-9066 Excludes induction heating.
Alternate Parts: 342400000000, 3424-0000-0000, 127857, 3424-01-196-9066, 01-196-9066, 3424011969066, 011969066
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) | 
|---|---|---|---|
| 34 | DEC 15, 1984 | 01-196-9066 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) | 
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-01-196-9066
| Part Number | Cage Code | Manufacturer | 
|---|---|---|
| 3424-0000-0000 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ | 
| 127857 | 17068 | DESPATCH INDUSTRIES LIMITEDPARTNERSHIP | 
Technical Data | NSN 3424-01-196-9066
| Characteristic | Specifications | 
|---|---|
| DESIGN TYPE | ANY ACCEPTABLE | 
| MOUNTING TYPE | FLOOR | 
| MAXIMUM OPERATING TEMP | 1600.0 DEG FAHRENHEIT | 
| OPERATING TEMP RANGE | +300.0 TO +1600.0 DEG FAHRENHEIT | 
| TEMP CONTROL DEVICE TYPE | AUTOMATIC | 
| CURRENT TYPE | AC | 
| VOLTAGE IN VOLTS | 220.0 | 
| FREQUENCY RATING | 60.0 HERTZ NOMINAL | 
| PHASE | THREE | 
| TILTING HEARTH | NOT INCLUDED | 
| WORK HOLDING BASKET | NOT INCLUDED | 
| ACCESS OPERATION METHOD | ANY ACCEPTABLE | 
| COUNTERWEIGHT | NOT INCLUDED | 
| EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |