NSN 3424-00-172-4560
Part Details | ELECTRIC HEAT TREATING FURNACE
3424-00-172-4560 Excludes induction heating.
Alternate Parts: 342451122420, 3424-5112-2420, MILF80207, 3424-00-172-4560, 00-172-4560, 3424001724560, 001724560
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
34 | SEP 01, 1972 | 00-172-4560 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-00-172-4560
Part Number | Cage Code | Manufacturer |
---|---|---|
3424-5112-2420 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ |
MILF80207 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 3424-00-172-4560
Characteristic | Specifications |
---|---|
DESIGN TYPE | CONVECTION CAR |
MOUNTING TYPE | FLOOR |
MAXIMUM OPERATING TEMP | 1250.0 DEG FAHRENHEIT |
OPERATING TEMP RANGE | +300.0 TO +1250.0 DEG FAHRENHEIT |
TEMP CONTROL DEVICE TYPE | AUTOMATIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 460.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | THREE |
INSIDE LENGTH | 120.000 INCHES NOMINAL |
INSIDE WIDTH | 60.000 INCHES NOMINAL |
INSIDE HEIGHT | 60.000 INCHES NOMINAL |
TILTING HEARTH | NOT INCLUDED |
WORK HOLDING BASKET | NOT INCLUDED |
DOOR/OPENING LOCATION AND QUANTITY | DOOR IN FRONT 1 |
ACCESS OPERATION METHOD | CT ANY ACCEPTABLE |
COUNTERWEIGHT | NOT INCLUDED |
EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |
TEST DATA DOCUMENT | 81349-MILF80207 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
NONDEFINITIVE SPEC/STD DATA | 1 TYPE AND A STYLE AND 2 CLASS |
DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY POWER SUPPLY PROVIDED |