NSN 2920-00-090-1533

Part Details | IGNITION MAGNETO

2920-00-090-1533 An electric generator whose field poles are permanent magnets and which is used to generate electrical energy for the purpose of igniting the combustible mixture in internal combustion engine cylinders. Spark distribution may be accomplished by a distributor portion of the magneto or by a separate item.

Alternate Parts: FMXE4B11F, FMXE4B11F, FMXE4B11F, 2920-00-090-1533, 00-090-1533, 2920000901533, 000901533

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
29JAN 01, 196300-090-153300113 ( MAGNETO, IGNITION )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 2920-00-090-1533
Part Number Cage Code Manufacturer
FMXE4B11F82796COLTEC INDUSTRIES INC.DBA FAIRBANKS MORSE ENGINE
FMXE4B11F03764COLTEC INDUSTRIES INCFMD ELECTRONICS DIV
FMXE4B11F7PZX0FAIRBANKS MORSE, LLC
Technical Data | NSN 2920-00-090-1533
Characteristic Specifications
IMPULSE QUANTITY PER REVOLUTION4
IGNITION TYPE FOR WHICH DESIGNED SINGLE
SPARK DISTRIBUTION METHOD GAP
SHAFT ROTATION DIRECTION COUNTERCLOCKWISE
DISTRIBUTOR CAP INCLUDED
SECONDARY TERMINAL TYPE THREADED
SPARK PLUG TERMINAL ACCOMMODATION THREAD SERIES UNEF
SPARK PLUG TERMINAL ACCOMMODATION THREAD DIAMETER0.688 INCHES NOMINAL
SPARK PLUG TERMINAL ACCOMMODATION THREAD QUANTITY PER INCH24
BODY MATERIAL ALUMINUM ALLOY
MOUNTING METHOD FLANGE
MOUNTING STANDARD CONTROLLING AGENCY SAE
MOUNTING STANDARD NUMBERJ556
MOUNTING FACILITY SLOT AND THREADED HOLE
MOUNTING FACILITY QUANTITYA1$$A1
MOUNTING FACILITY THREAD SERIES UNC
MOUNTING FACILITY THREAD DIAMETER0.375 INCHES NOMINAL
MOUNTING FACILITY THREAD QUANTITY PER INCH16
MOUNTING SLOT LENGTH1.137 INCHES NOMINAL
MOUNTING SLOT WIDTH0.403 INCHES MINIMUM AND 0.414 INCHES MAXIMUM
DISTANCE BETWEEN MOUNTING FACILITY CENTERS4.182 INCHES MINIMUM AND 4.194 INCHES MAXIMUM
PERFORMANCE TYPE HIGH TENSION
ROTATION ELEMENT TYPE PERMANENT MAGNET ROTOR
POLE QUANTITY2
CONTACT SET QUANTITY1
DRIVE CONNECTION TYPE IMPULSE COUPLED
ENVIRONMENTAL PROTECTION FUNGUS RESISTANT
FEATURES PROVIDED RADIO INTERFERENCE SHIELDING